Get Free Quote

Anti-Glare Systems

Median glare screens and blades that cut headlight glare between opposing carriageways.

Specification parameters

1. Product Range

FRP Anti-Glare ScreenGlass-fibre reinforced polyester blade for the median guardrail or barrier top
Steel Anti-Dazzle PanelSteel sheet blade, hot-dip galvanised and powder coated
Mounting HardwareBase bracket or rail clamp, bolted to the median guardrail or barrier
Blade Materials in UseFRP (SMC / DMC), plastics (HDPE, PVC, ABS) and steel

2. Blade Dimensions

Height700 – 1100 mm
Width140 – 290 mm
ThicknessFRP blades 4.0 – 5.0 mm; steel sheet 0.8 – 3 mm
Common FRP Sizes (H × W × t)850 × 200 × 4.5; 900 × 220 × 4.5; 900 × 260 × 5.0; 900 × 280 × 5.0; 1000 × 200 × 4.0 / 5.0 mm
Fixing HolesØ8 – 10 mm (GB/T 24718-2009)
TolerancesHeight ±5 mm, width ±2 mm (GB/T 24718-2009)

3. Material & Finish

FRP BladeGlass-fibre roving and continuous mat with unsaturated polyester resin and fillers; pultruded or compression-moulded
FRP Strength (supplier data)Tensile ≥ 180 MPa; bending ≥ 198 MPa
Steel BladeCarbon steel, galvanised steel or stainless steel sheet
Steel FinishHot-dip galvanised; powder coated
Zinc Coating (ISO 1461, mean minimum)395 g/m² (55 µm) for steel 1.5 – 3 mm; 505 g/m² (70 µm) for steel over 3 – 6 mm
ColourFRP green, through-coloured; steel colour to order

4. Layout & Shading Angle

Shading Angle Formulaβ = arctan(b / L), where b = blade width and L = blade spacing (JTG/T D81-2017)
Shading Angle8° on straight runs; 8 – 15° on horizontal and vertical curves
Blade Spacing50 – 100 cm; reduced on curves
Design Eye / Headlamp HeightTrucks 2.0 m / 1.0 m; cars 1.3 m / 0.8 m (JTG/T D81-2017)
US Design GuidanceCutoff angle 20° on tangents; glare screening for medians up to 6.1 m wide (NCHRP Synthesis 66)

5. Performance Requirements (GB/T 24718)

Wind LoadF ≥ C × S, where C is the wind-load constant (1647.5) and S is the effective wind-bearing area of the blade
Wind-Load Constants (2023 edition)Grouped by region: 1647.5 N/m² and 2685.4 N/m²
Deformation≤ 10 mm/m after wind-load test (2009 edition)
Fatigue LoadAdded for W-type blades in the 2023 edition
Referenced TestsDensity, Barcol hardness and oxygen index (FRP); xenon-arc weathering; salt spray; chemical resistance; coating adhesion

6. Standards

China (product)GB/T 24718-2023 (replaces GB/T 24718-2009; JT/T 333-1997 withdrawn in 2010)
China (design)JTG D81-2017, JTG/T D81-2017
GalvanisingISO 1461
USA (guidance)NCHRP Synthesis 66, Glare Screen Guidelines

7. Applications

Expressway MediansOn the central median guardrail or between guardrails
Median OpeningsOn movable guardrail at central median openings
Concrete Median BarriersAnchored to the barrier top