Mile Marker
Route, kilometre and boundary markers in reflective sheeting on steel or plastic bodies.

Kilometre Marker Post
Kilometre marker post with reflective facing and its own number. Produced against the numbering schedule you supply; proofing before production.
Route and Boundary Marker
Route and boundary marker in reflective sheeting on a steel plate or moulded body. Numbering and legend confirmed against the schedule before the run starts.Specification parameters
1. Product Range
| Kilometre Marker Post | Numbered plate on a single post at the road edge; white numerals on green |
|---|---|
| Reference Location Sign (Mile Marker) | 1-, 2- or 3-digit vertical plate showing an integer distance point along the route |
| Intermediate Reference Location Sign | Plate showing tenths of a distance unit with a decimal point, for closer spacing |
| Enhanced Reference Location Sign | Taller vertical plate carrying cardinal direction, route shield and distance |
2. Plate Dimensions
| Kilometre marker (Alberta) | 250 mm wide × 450 / 600 / 750 mm high for 1 / 2 / 3 digits; corner radius 38 mm |
|---|
3. Legend & Colour
| Colour | White numerals and white border on green background |
|---|---|
| Numeral height | 152 mm (6 in) on conventional roads; 254 mm (10 in) on freeways and expressways; 150 mm on the Alberta kilometre marker |
| Word legend | "MILE" in 102 mm (4 in) letters on US signs; 100 mm letters on the Alberta kilometre marker |
| Border | 10 mm white edge (Alberta kilometre marker) |
| Enhanced signs | Blue or green background, one colour per jurisdiction; legend min. 152 mm (6 in); route shield min. 305 mm (12 in) |
4. Plate & Sheeting
| Plate substrate | Flat aluminium sheet, min. 2 mm (Alberta kilometre marker); 2.5 mm aluminium alloy is the usual UK sign default; 1.2 mm coated steel sheet is an alternative where theft is a concern |
|---|---|
| Face sheeting | Type III or IV high-intensity retroreflective sheeting (ASTM D4956) specified for kilometre markers (Alberta) |
| ASTM D4956 types | I, II (engineering grades); III, IV (high-intensity); VIII, IX, XI (microprismatic) for permanent signs; type number does not indicate performance order |
| Retroreflection class (EN 12899-1) | RA1 (lowest grade) or RA2; UK National Annex adds R2, R3B, R3C |
| Wind load class (EN 12899-1) | WL0 – WL9, specified per project; UK practice example 1200 N/m² (WL6) |
5. Post & Installation
| Post | 100 × 100 mm treated timber or approved steel post (Alberta); back-to-back plates on a single post on two-lane undivided roads |
|---|---|
| Mounting height | Bottom of sign 1.5 m above road surface (Alberta); min. 1.22 m (4 ft) above near roadway edge (MUTCD) |
| Lateral offset | 6 m from the white shoulder line (Alberta); up to 9.1 m (30 ft) from the pavement edge (MUTCD) |
| Side of road | Right-hand side; median permitted where the right side is restricted (MUTCD) |
| Passive safety (EN 12767) | Steel or aluminium posts of Ø 89 mm or less are deemed passively safe if no stronger in bending than an S355 tube of that diameter with 3.2 mm wall |
6. Spacing & Numbering
| Zero point | Numbering starts at the south and west limits of the route and increases north and east |
|---|---|
| Spacing | 4 km intervals, reduced to 2 km on complex alignments (Alberta); intermediate signs at 0.1 mile or other regular spacing (MUTCD) |
| Placement tolerance | Up to 15 m (50 ft) either way (MUTCD); up to 200 m either way (Alberta), otherwise moved or omitted |
| Continuity | Continuous numbering along each route; on overlapping routes only one route keeps continuity |
7. Steel Post Galvanizing
| ASTM A123 (pipe & tubing) | 45 µm (< 3.2 mm wall), 75 µm (≥ 3.2 mm wall) minimum average |
|---|
8. Standards
| USA | MUTCD Chapter 2H (Reference Location Signs); ASTM D4956 |
|---|---|
| Europe | EN 12899-1 (fixed vertical signs); EN 12767 (passive safety of support structures) |
| Canada (example) | Alberta Transportation, Kilometre Markers, drawing TCS-A-550 |
| Galvanizing | ISO 1461; ASTM A123/A123M |