Specification parameters

1. Product Range

Surface-mount flexible warning postPolymer post on a bolt-down base; can be knocked flat by a vehicle and springs back upright
Height variants450 / 750 / 1000 mm; 750 mm is the common size
Ground-fixed flexible delineator postPost designed to deflect on impact and return to vertical (EN 12899-3 type D3)
Structure-mounted delineator postPost fixed to bridges, barriers or guardrails (EN 12899-3 type D4)

2. Dimensions

Height750 mm (450 / 1000 mm options)
Post diameter80 mm
Base diameter200 mm
Fixing points3 anchor holes in the base plate, for asphalt or concrete
Unit weight (750 mm)Approx. 1.3 kg

3. Material & Colour

Body materialTPU or PU; PVC and EVA formulations also used
AdditivesUV stabilizers and cold-resistant additives in the body compound
ColourOrange, red, yellow; white is required for road-edge delineator posts under some national rules

4. Retroreflective Bands

SheetingHigh-intensity micro-prismatic retroreflective bands
Band count2 – 3 bands on 750 mm posts
MUTCD tubular marker < 1067 mm (42 in)Two 76 mm (3 in) white bands, top band max. 51 mm (2 in) from the top, max. 152 mm (6 in) between bands
MUTCD tubular marker ≥ 1067 mm (42 in)Four alternating orange and white stripes, 102 – 152 mm (4 – 6 in) wide, top stripe orange
EN 12899-3 retroreflector typesR1 sheeting (min. class RA2 to EN 12899-1); R2 microprismatic; R3 glass bead
Curved surfaceSign sheeting tested flat may be applied where the post radius is 40 mm or more (Finnish rule under EN 12899-3)

5. Performance Classes & Test Basis

EN 12899-3 post typesD1 not re-usable after impact test; D2 re-mountable; D3 deflects and returns to vertical; D4 fixed to structures
EN 12899-3 deflection classesWL0 not defined; WL1 max. 15 % of height above ground; WL2 max. 5 %
Permanent deflectionNot more than 5 % of height above ground after the wind-load test (D1 – D3)
Retroreflector impact classesDH0, DH1, DH2
US DOT impact test (typical)10 impacts by a passenger car at 88 km/h (55 mph); post self-erects within 10° of vertical (5° in some states) and retains 50 – 60 % of its reflective sheeting
Test temperatures (US)Impacts split between approx. 0 °C (32 °F) and 29 °C (85 °F)

6. Size Rules in Standards

MUTCD tubular markerMin. 457 mm (18 in) high and 51 mm (2 in) wide facing traffic; min. 711 mm (28 in) on freeways and high-speed roads
MUTCD material ruleCan be struck without damaging the impacting vehicle; channelizing devices shall be crashworthy
Finnish rule under EN 12899-3Post width facing traffic 80 – 150 mm; black reflector field approx. 250 – 300 mm high

7. Standards

EuropeEN 12899-3 (delineator posts and retroreflectors); EN 12899-1 (retroreflection classes)
USAMUTCD Section 6F.65 (tubular markers); ASTM D4956 (sheeting); NTPEP flexible delineator evaluation used by state DOTs