Lamp Poles
Solar and mains street lighting columns, including camera and signage arms.

Street Lighting Column
Galvanised street lighting column, 6-12 m, straight or tapered, single or double arm. Base plate and anchor bolts supplied; the luminaire is a separate item.
Traffic Light Pole
Cantilever traffic light pole for signalised junctions: galvanised steel pole with single or double mast arm for signal heads, countdown timers and signs.
Double-Arm Street Light Pole
Double-arm street light pole for dual carriageways and junctions. Columns 8-12 m with twin arms, base plate and anchor template, hot-dip galvanised.
Solar Street Light Pole
Solar street light pole with panel bracket and battery box for roads without mains power. Column and bracket supplied; panels and luminaire separate.Specification parameters
1. Product Range
| Single-Arm Street Lighting Column | Residential and urban roads; conical, octagonal or round shaft |
|---|---|
| Double-Arm Street Light Pole | Wide roads, dual carriageways and major intersections |
| Solar Street Light Pole | Column with top panel bracket; 6 – 8 m poles typically carry 20 – 30 kg of panel and luminaire |
| Post-Top Column | Lantern mounted on the column top; EN 40-2 covers post-top columns up to 20 m |
2. Column Dimensions
| Height | 6 / 8 / 10 / 12 m typical for roads; EN 40-2 nominal post-top heights 3 – 20 m, bracketed columns up to 18 m |
|---|---|
| Shape | Conical (most common), octagonal (bent plate), round or polygonal |
| Top / bottom diameter | Approx. 60 – 140 mm top and 140 – 300 mm bottom across 6 – 12 m columns (supplier reference tables) |
| Wall thickness | 3.0 mm (6 m) to 4.0 – 5.0 mm (12 m); heavier sections for taller or high-wind designs |
| Arm | Single or double; projection 0.5 – 3.0 m; rise typically 5 – 15°; luminaire spigot 35 – 60 mm |
| Bracket projection guidance | EN 40-2 recommends projection ≤ h/4; UK highway practice: lesser of 0.25 × height or 3 m |
| Longitudinal seam | Automatic submerged-arc welding (supplier data) |
3. Base, Door & Cable Entry
| Base plate | Approx. 300 × 300 × 16 mm (6 m) to 400 × 400 × 20 mm – 500 × 500 × 25 mm (12 m); final size by structural calculation |
|---|---|
| Anchor bolts | 4 × M20 (6 m) to 4 × M24 – M27 (10 – 12 m); hot-dip galvanized J-bolts with template |
| Foundation depth | Approx. 0.8 – 1.2 m for small poles, 1.2 – 2 m for medium poles |
| Door opening (EN 40-2) | Protection IP3X for doors and parts up to 2.5 m; compartment door impact test IK08 |
| Cableways (EN 40-2) | Min. Ø 18 mm from base to lantern; min. Ø 50 mm from cable entry to base |
4. Material
| Chinese GB | Q235B, Q355B (formerly Q345B) |
|---|---|
| European (EN 40-5) | Sheet and plate to EN 10025 (S185 excluded), e.g. S235JR, S355JR; hot-finished tube EN 10210; cold-formed tube EN 10219; stainless EN 10088 |
| American ASTM | A36; A572 high-strength option |
| Foundation bolts (EN 40-5) | Minimum mechanical properties of EN 10025 grade S235JR |
5. Surface Treatment
| Hot-dip galvanizing | Inside and outside of the shaft; to ISO 1461 or ASTM A123 |
|---|---|
| ASTM A123 (pipe & tubing) | 75 µm minimum average for 3.2 mm wall and above |
| Powder coating | Optional duplex system: galvanizing + polyester powder coat in RAL colours |
| EN 40-5 protection zones | Area A outside from top to ≥ 0.2 m above ground; Area B ground section incl. ≥ 0.25 m above ground; Area C inside |
6. Structural Design Basis
| EN 40-3-1 / 3-2 / 3-3 | Characteristic loads (wind, lantern, bracket); verification by testing (3-2) or by calculation (3-3) at the site reference wind velocity |
|---|---|
| AASHTO LRFD LTS | Basic wind speed set by mean recurrence interval (10 / 300 / 700 / 1700 years) according to traffic volume and risk category |
| AASHTO example (Iowa DOT) | 1700-year MRI, 53.6 m/s (120 mph) for Extreme I; 10-year MRI, 34.0 m/s (76 mph) for Service I |
| AASHTO fatigue loads | Galloping, vortex shedding, natural wind gust and truck-induced gust, scaled by a fatigue importance factor |
| Supplier wind ratings | 30 – 40 m/s for standard areas; 45 – 60 m/s for coastal areas; or to site data |
| Passive safety (EN 12767) | Non-energy-absorbing, low-energy-absorbing or high-energy-absorbing categories, where columns stand in the clear zone |
7. Standards
| Europe | EN 40-2, EN 40-3-1, EN 40-3-2, EN 40-3-3, EN 40-5; EN 12767 |
|---|---|
| USA | AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires, and Traffic Signals; ASTM A123 |
| Galvanizing | ISO 1461; GB/T 13912 (China) |
| Quality System | ISO 9001 |