Armco Barrier
Also known as: armco crash barrier, EN 1317 H1W3 guardrail, EN 1317 H2W3 guardrail, corrugated beam barrier
Two-wave corrugated beam in 4320 x 310 x 85 mm, hot-dip galvanised 550 or 1100 g/m2 both faces. Supplied as a system to the H1W3 or H2W3 class on the drawing.
- Choose this when
- Where the specification names a containment class rather than a profile, and the rail, post and blockout have to arrive as the system that class was written around.
- Choose another when
- Where the order is a drawing with a thickness and a post section and no standard at all — that is priced on the Crash Barrier page, from your sheet.
- Profile
- Two-wave corrugated beam
- Rail size (L x W x H)
- 4320 x 310 x 85 mm (4000 mm effective); 4130 mm also supplied for legacy EN layouts — custom sizes to drawing
- SampleSample available on request, freight at cost
- PaymentT/T, L/C at sight — terms confirmed on the quotation
- ShippingFOB / CIF from Qingdao or Tianjin
- Lead time5–20 days after drawing approval


Where it is used
Where the specification names a containment class rather than a profile. Buyers in the UK, Ireland, Australia and the Gulf write “Armco barrier, H2W3” or “EN 1317 H1W3” and expect the rail, post and blockout to arrive as one system — not a beam cut to length and matched on site.
Why the class changes the order
H1W3 and H2W3 are containment and working-width classes, so the answer is a system: beam, post spacing, blockout depth and bolt pattern are fixed together. A beam that matches the drawing but a post at a different spacing is no longer the class that was specified. That is why this page asks for the class first and the dimensions second.
What the name does not change
Armco is a trade name that became generic; the section is the same two-wave beam sold elsewhere as W-beam: 4320 x 310 x 85 mm, 3.0 or 4.0 mm, 8 x M16 per joint. What differs from an uncoated run is the zinc weight and the assembly — 550 or 1100 g/m2 both faces, post and blockout set from the class, and duplex powder to one RAL if the scheme calls for colour.
Specification parameters
Beam dimensions
| Profile | Two-wave corrugated beam |
|---|---|
| Rail size (L x W x H) | 4320 x 310 x 85 mm (4000 mm effective); 4130 mm also supplied for legacy EN layouts — custom sizes to drawing |
| Thickness | 3.0 / 4.0 mm — custom sizes to drawing |
| Mass per rail | approx. 49.2 kg (3.0 mm) / 65.6 kg (4.0 mm), before coating |
| Splice | 8 x M16 bolts per joint |
Containment and coating
| Containment class | H1W3 or H2W3, stated on the drawing; post spacing and blockout follow the class |
|---|---|
| Zinc coating | Hot-dip galvanised 550 / 1100 g/m2 both faces (= 275 / 550 g/m2 per side) |
| Coating scope | Duplex polyester powder available to one stated RAL across rails, posts and blockouts |
Supply
| Steel grade | Q235B (S235JR) |
|---|---|
| Supply form | System: rail, post, blockout and bolt kit |
| Matching post | Round 114 x 4.5 mm, or C-section 150 x 75 x 4.5 mm — custom sizes to drawing |
| Typical market | UK, Ireland, Australia, Gulf — specifications written to EN 1317 |
Frequently asked questions
Is Armco the same as W-beam?
Armco is a trade name that became the generic word for the corrugated steel barrier; the profile is the same two-wave beam. What differs is how the order is written, not the steel.
H1W3 or H2W3 — which do I need?
That is a road-authority decision, taken from the traffic and the drop behind the barrier. Send the class with the drawing; post spacing and blockout depth are set from it.
Why are both 4130 and 4320 mm supplied?
4320 mm is the metric length used in most EN layouts; 4130 mm still appears on legacy drawings. Once lapped they cover the same effective run.
Can the finish be duplex?
Yes. Polyester powder over the galvanising, one RAL across rails, posts, blockouts and bolt heads.