EN 1317 H2W3 Thrie-Beam Guardrail
Also known as: H2W3 thrie beam, 506 mm three-wave barrier, H2 containment guardrail, EN 1317 three-wave system
Three-wave thrie-beam to EN 1317 H2W3: 4,820 x 506 x 85 mm, 4.0 mm sheet, 1,100 g/m2 zinc both faces, supplied as the system the class was written around.
- Choose this when
- Where the drawing names H2W3 and the run has to be the three-wave system that class was written around, with post spacing and blockout set from the class.
- Choose another when
- Where only the profile is specified and the class is open — the Thrie-Beam page covers the section range and the coating options without fixing a class.
- Profile
- Three-wave thrie-beam to EN 1317 H2W3 layouts
- Rail size (L x W x H)
- 4,820 x 506 x 85 mm — custom sizes to drawing
- SampleSample available on request, freight at cost
- PaymentT/T, L/C at sight — terms confirmed on the quotation
- ShippingFOB / CIF from Qingdao or Tianjin
- Lead time5–20 days after drawing approval


Where it is used
Where the drawing names H2W3 and expects the three-wave system that was written around that class: 506 mm wide, 4.0 mm sheet, 4,820 mm rails. This is not a general thrie-beam page — it is the specific system, and the post spacing and blockout come from the class rather than from the profile.
What H2W3 fixes
H2 is the containment level and W3 the working width. Together they fix how much energy the barrier takes and how far it deflects, which in turn sets post spacing, blockout depth and bolt pattern as one assembly. Change one of them without the others and the run is no longer the class, even if every part individually matches the drawing.
What the class does not change
The beam is still the three-wave section: 506 x 85 mm, 4.0 mm, 12 bolts per splice. What is specific here is the coating weight — 1,100 g/m2 both faces — and the 4,820 mm length that the H2W3 layouts are drawn to.
Specification parameters
Beam dimensions
| Profile | Three-wave thrie-beam to EN 1317 H2W3 layouts |
|---|---|
| Rail size (L x W x H) | 4,820 x 506 x 85 mm — custom sizes to drawing |
| Thickness | 4.0 mm — custom sizes to drawing |
| Splice | 12 bolts per joint (2 rows of 6) |
Containment
| Class | H2W3 — H2 containment, W3 working width |
|---|---|
| Post spacing | Set by the class and stated on the drawing |
| Blockout | Depth and bolt pattern follow the class |
Coating and supply
| Zinc coating | Hot-dip galvanised 1,100 g/m2 both faces (= 550 g/m2 per side) |
|---|---|
| Finish | Plain galvanised; duplex powder on request |
| Supply form | System: rail, post, blockout and bolt kit |
| Typical market | Europe and any project written to EN 1317 |
Frequently asked questions
What does H2W3 mean?
H2 is the containment level and W3 the working width — the distance the barrier deflects under impact. Both come from the road authority's risk assessment, not from the profile.
Why 4,820 mm?
It is the length the H2W3 layouts are drawn to. The effective run is set by the lap and the post spacing, both of which come from the class.
Why 1,100 g/m2?
It is the heavier of the two zinc weights used in EN work, specified where the run is exposed or the design life is long. 550 g/m2 is available where the drawing allows it.
Is this the same as the Thrie-Beam page?