Get Free Quote

W-Beam Guardrail Dimensions: How to Read a Drawing

Nominal against effective length, the 310 / 311 / 312 mm width question, depth against thickness, and the hole pattern: how to read every number on a W-beam drawing.

W-beam profile dimensions: 311 mm wide, 85 mm deep, 194 mm wave pitch

A W-beam drawing carries about eight numbers, and quotations routinely go out against the wrong one. Length and effective length differ by the lap. The width is printed as 310, 311 or 312 mm depending on which document is open. Depth and thickness are two different figures that get swapped more often than any other pair in this trade. Here is what each one controls.

W-beam profile drawing showing 311 mm overall width, 85 mm depth and 194 mm wave pitch
Two-wave W-beam profile. The three numbers a buyer needs first are the overall width, the wave depth and the pitch between crests.

The numbers that matter, in the order they decide a price

  • Nominal length — the steel you are buying, end to end.
  • Effective length — the run one rail covers once it laps the next. This is the figure that sizes the order.
  • Width and depth — the profile itself, normally 310 x 85 mm in metric work.
  • Thickness — a separate number, 3.0 or 4.0 mm, that decides mass and freight.
  • Hole pattern — eight bolts per joint on a W-beam, and two different slotted holes.

Length: nominal against effective, and the lap in between

A rail is made 4320 mm long and covers 4000 mm of barrier. The 320 mm difference is the lap: each rail is bolted over the end of the one before it, so the steel overlaps rather than ends. Order by nominal length and the run comes out about 7% short.

Two other lengths turn up. 4130 mm still appears on older European drawings; once lapped it covers a similar run and is not a different product. North American work is written to 3,810 mm effective, which is 12 ft 6 in [1]. None of these are interchangeable on a drawing that names one of them, because the hole pattern is drilled for that lap.

The practical arithmetic is one line of the drawing: rails needed equals the run divided by the effective length, rounded up, plus one for the first lap. A 1 km run at 4,000 mm effective is 250 rails, and the quote should say 251.

Width: why 310, 311 and 312 mm describe the same beam

Open a metric catalogue and the two-wave beam is 310 mm wide. Open our drawing and it measures 311 mm across. Open AASHTO M 180 and it is 312 x 83 mm [1]. The gap between them is one to two millimetres, and it comes from which document is being read rather than from the steel: the same profile is quoted to the nearest round number in each system.

That matters for one reason only — a buyer comparing quotations sees three different widths and concludes they are three different products. They are not. What does change between documents is the depth, and that is covered next.

Depth: the 85 mm that carries the load

The 85 mm is measured from the face of the crest to the back of the trough. It is the dimension that gives the beam its stiffness: a deeper wave resists bending with the same steel thickness, which is why the three-wave thrie-beam reaches a higher containment class at the same gauge by going to 506 mm of width with a third wave rather than by using a heavier plate.

AASHTO quotes 83 mm for the same reason the width is quoted differently [1]. A drawing that shows 83 mm is an M 180 drawing, and the rest of it — the hole pattern, the lengths, the class — will be M 180 as well. Do not mix the depth from one system with the length from another.

Thickness is a separate number, not part of the profile

Metric work runs 3.0 or 4.0 mm. The same rail weighs about 49.2 kg at 3.0 mm and about 65.6 kg at 4.0 mm, before coating, and that difference shows up in freight and in price long before it shows up in performance. AASHTO writes the same choice as Class A at 2.67 mm (0.105 in) and Class B at 3.43 mm (0.135 in) [1].

The mistake to avoid is treating thickness as a free upgrade. A 4.0 mm rail is not simply a stronger version of the 3.0 mm one; it is a different order, with different mass, different handling and, in EN work, a different class it can be attested to. If the drawing says 3.0 mm and the quotation says 4.0 mm “for safety”, the two documents are no longer describing the same barrier.

Holes: eight bolts, and two slotted patterns

A W-beam joint is eight M16 bolts. The thrie-beam joint is twelve, in two rows of six. Both counts are fixed by the profile, not by the project, and both appear on the drawing as the hole pattern at each end.

The drawing also shows slotted holes — 22 x 29 mm and 19 x 64 mm on the standard two-wave profile. These ovals are not damage and not a manufacturing shortcut. They exist so the rail can be positioned and shimmed during installation, and so a joint can be pulled tight on uneven ground. A drawing with round holes where the standard has slots is a different part.

Reading one line of a specification

Take a typical line: 4320 x 310 x 85 mm, 3.0 mm, 8 x M16, hot-dip galvanised 600 g/m2. In order, that says: the rail is 4320 mm long and covers 4000 mm once lapped; the profile is 310 mm wide and 85 mm deep; the steel is 3.0 mm, so the rail is about 49.2 kg before coating; the joint is eight bolts; and both faces carry 600 g/m2 of zinc, which is 300 g/m2 per side.

Everything a quotation needs is now defined except the post. That is deliberate — the post is a separate line, and it is the one most often left out.

The same numbers on a thrie-beam

A three-wave beam is drawn the same way and read the same way; only the figures change. Width goes from 310 to 506 mm because a third wave is added, depth stays at 85 mm, and the joint doubles to twelve bolts. The point of the third wave is stiffness: it raises the beam’s resistance to bending without going to a heavier plate, which is why a 4.0 mm thrie-beam can carry a higher containment class than a 4.0 mm W-beam.

ProfileWidthDepthNominal lengthJointUsual thickness
W-beam, two-wave310 mm85 mm4,320 mm8 x M163.0 / 4.0 mm
Thrie-beam, three-wave506 mm85 mm4,820 mm12 bolts4.0 mm
Three-beam506 mm85 mm4,320 mm12 x M164.0 mm

Two consequences for a drawing. First, a three-wave rail is roughly 15% wider on the lorry, so freight is priced on a different deck space even when the tonnage looks similar. Second, the twelve-bolt joint does not interchange with the eight-bolt one: a thrie-beam rail will not lap onto a W-beam run, whatever the post spacing says. The two families are supplied as separate systems, and the thrie-beam page carries the full range; where a containment class is fixed, the H2W3 system is the specific order.

What the drawing still has to say

  • Post: the profile, the spacing, and how it is fixed — driven, flanged base plate, or cast in.
  • Mounting height: measured to a named point on the rail, usually the top. A drawing that gives only a post length has not stated the height.
  • Blockout: the depth of the spacer between rail and post, which is set by the class rather than chosen.
  • End treatment: fishtail, bullnose or flared terminal, each with its own length and bolt pattern.
  • Finish: zinc weight, and a RAL number plus powder thickness if the run is coated.

Where any of those is missing, the quotation comes back as an assumption, and the assumption is usually the cheapest option that fits the drawing. That is not a supplier being difficult; it is the only thing a factory can do with an incomplete sheet.

Where these numbers come from

The profile dimensions and the hole patterns on this page are from our own production drawings, which are open for inspection on request. The 312 x 83 mm profile, the 2.67 and 3.43 mm classes, the 3,810 mm effective length and the 550 / 1,100 g/m2 zinc types are as published in AASHTO M 180 [1]. The working width and containment classes referenced on the related pages are from EN 1317-2 [2]. Where the two systems disagree by a millimetre, the drawing you are quoting from decides.

Frequently misread

  • Length against effective length. 4320 mm is the steel; 4000 mm is the run. Quoting on the first under-orders the job.
  • Depth against thickness. 85 mm is the wave; 3.0 mm is the plate. They are not alternatives.
  • Width against class. A wider beam is not automatically a higher class. The class belongs to the whole system: rail, post, blockout and spacing.
  • Slotted holes as a defect. They are designed, and the pattern is part of the specification.

References

[1] AASHTO M 180, Standard Specification for Corrugated Sheet Steel Beams for Highway Guardrail — 312 x 83 mm profile; Class A 2.67 mm (0.105 in), Class B 3.43 mm (0.135 in); Type I 550 g/m2, Type II 1,100 g/m2; 3,810 mm effective length.

[2] EN 1317-2, Road restraint systems — Performance classes, impact test acceptance criteria and test performance for safety barriers.

More articles